Answer by User323693 for AMS1117-3.3 over-heating and blow up way below max...
Summary: go with a buck regulator which saves power and space. If linear regulator is still a choice, due to the huge voltage difference between input and output (12-3.3 = 8.7 V) and the current...
View ArticleAMS1117-3.3 over-heating and blow up way below max current
I am designing a circuit for my home automation system. To give a gist, I have a 12V 3.5A supply. I need to operate multiple loads off it.One of the Loads is a ESp12E module.Esp12e module ----- Max...
View Article